Product Details:
Type of Cooling Tower | Forced Draft Cooling Tower |
Cooling Capacity (Ton of Refrigeration) | 21 - 50 TR |
Tower Material | FRP |
Type | Induced Draft Type, Forced Draft Type |
Usage/Application | Industrial |
Shape | Square |
Supply Phase | Three Phase |
Motor | Dia of Fan | In / Out Size | Overall Dimension | Shipping Weight | Operating Weight |
|
|
|
|
L | H | P | HP / RPM |
| NB | LxWxH in mm | kg. | kg. |
|
SCT-400TR | Tick | Tick | Tick | 15 / 360 | 2400 (FRP) | 10" / 10" | 4000 x 4000 x 3965 | 2150 | 4300 |
SCT-500TR | Tick | Tick | Tick | 20 / 360 | 3000 (FRP) | 10" / 10" | 4500 x 4500 x 3965 | 2400 | 4700 |
SCT-600TR | Tick | Tick | Tick | 20 / 270 | 3600 (FRP) | 10" / 10" | 5200 x 5200 x 4465 | 2700 | 5200 |
SCT-800TR | tick | tick | tick | 25 / 270 | 4270 (FRP) | 12" / 12" | 6000 x 6000 x 4465 | 3200 | 5600 |
SCT-1000TR | Tick | Tick | Tick | 25 / 200 | 4800 (FRP) | 14" / 14" | 6700 x 6700 x 5020 | 3800 | 5900 |
Product Details:
Tower Material | FRP |
Type | Natural Draft Type, Induced Draft Type, Forced Draft Type |
I Deal In | New Only |
Installation/After Sales Service Required | Yes |
Weather Proof | Yes |
Material | Fiberglass Reinforced Polyester |
Automation Grade | Automatic |
Phase | Single |
Product Details:
Type of Cooling Tower | Forced Draft Cooling Tower |
Cooling Capacity (Ton of Refrigeration) | 51 - 100 TR |
Tower Material | FRP |
Type | Induced Draft Type, Forced Draft Type, Natural Draft Type |
Usage/Application | Industrial |
Shape | Square |
Supply Phase | Three Phase |
GAS-025/1 | 1300x1300x1345 | 2"/2"NB | 1060 | 1 | 448 | 460 |
GAS-030/1 | 995x995x1345 | 2"/2"NB | 750 | 1 | 252 | 270 |
GAS-045/1 | 1300x1300x1345 | 2"/2"NB | 1060 | 1 | 448 | 472 |
Product Details:
I Deal In | New Only |
Installation/After Sales Service Required | Yes |
Weather Proof | Yes |
Design Wet Bulb Temp | 29 Degree Celsius |
Vibration Level | 2 mm/sec |
Relative Humidity | 80% |
Noise Level | 25 DB |
Minimum Approach | 2 Degree Celsius |
Maximum Range | 50 Degree Celsius |
Product Details:
Type | Forced Draft Type, Induced Draft Type, Natural Draft Type |
Tower Material | FRP |
I Deal In | New Only |
Inlet Water Temperature | 75 to 90 Deg C |
Outlet Water Temperature | Amp + 4 Deg |
Outlet temperature (degree Celsius) | 45 |
Tower Type | Forced Draft |
Capacity | 150 to 2000 kVA |
Capacity | Approx. Water Circulated lpm | Loss of Water/Day Litres | Cost of Water Conserved / Day INR |
1.0 MW | 1100 | 31,680 | 1,584.00 |
2.0 MW | 2200 | 62,400 | 3,120.00 |
3.0 MW | 3250 | 93,600 | 4,680.00 |
4.0 MW | 4400 | 1,26,720 | 6,336.00 |
5.0 MW | 5500 | 1,58,400 | 7,920.00 |
Product Details:
Type | Induced Draft Type |
I Deal In | New Only |
Installation/After Sales Service Required | Yes |
Weather Proof | Yes |
Shape | Round |
temperature | 4 - 10 Degree C |
Tower Material | FRP |
Sl. No. | Model Variance | Motor | Dia of Fan | In / Out Size | Overall Dimension | Shipping Weight | Operating Weight | ||
L | H | P | HP / RPM | . | NB | DxH in mm | kg. | kg. | |
GCT-7.5 | 0.5 HP / 1440 | 450 (PVC) | 1½" / 1½" | 930 x 1500 | 90 | 225 | |||
GCT-10 | 0.5 HP / 1440 | 450 (PVC) | 1½" / 1½" | 930 x 1690 | 90 | 340 | |||
GCT-15 | 0.75 HP / 1440 | 700 (FRP) | 2" / 2" | 1180 x 1650 | 90 | 440 | |||
GCT-20 | 1 HP / 950 | 750 (NL) | 2" / 2½" | 1380 x 1800 | 110 |
Product Details:
Usage/Application | Preferred as per client |
Brand | Gem Equipments |
Fan Diameter | Standard |
Features | Standard |
Height | Standard |
Dimension | Standard |
Weight | Standard |
Product Details:
Tower Material | FRP |
Type | Forced Draft Type, Natural Draft Type, Induced Draft Type |
I Deal In | New Only |
Installation/After Sales Service Required | Yes |
Weather Proof | Yes |
Power | 15 kW |
Usage | Industrial |
Voltage | 380 V |